Jay Plast Logo
Back to Insights
November 2, 2026

How to Read a Plastic Technical Data Sheet (TDS): MFI, Tensile Strength, Impact, HDT, RTI & Shrinkage Explained

Every plastic grade comes with a Technical Data Sheet (TDS): a page full of numbers, test standards, and units. Buyers and engineers use it to compare grades, approve materials, and decide whether a cheaper alternative will work. But data sheets are easy to misread. Two grades can look equal on paper and behave very differently in your mould, simply because the numbers were measured in different ways.

At Jay Plast, we share data sheets for every grade we supply, from ABS and polycarbonate to nylon, PBT, POM, and PPS. In this guide, we explain the most important properties on a TDS, what they mean for your part, and the common mistakes to avoid when comparing grades.


1. TDS, COA and SDS: What Is the Difference?

DocumentWhat It Tells YouWhen You Need It
TDS (Technical Data Sheet)Typical properties of a gradeSelecting and comparing materials
COA (Certificate of Analysis)Measured results for one specific batchQuality checks on incoming material
SDS / MSDS (Safety Data Sheet)Safety, handling, storage, and hazard informationFactory safety and compliance

A TDS shows typical values, not guaranteed minimums. If a property is critical to your part, ask for the COA or agree a specification with your supplier.


2. Know the Test Standard: ISO vs. ASTM

Most data sheets use either ISO (international) or ASTM (American) test methods. They use different specimen sizes and conditions, so the numbers cannot be compared directly.

The most common trap is impact strength:

  • ISO 180 / ISO 179 (Izod / Charpy): Reported in kJ/m².
  • ASTM D256 (Izod): Reported in J/m.

There is no exact conversion between them. Always compare grades using the same test standard.


3. The Key Properties, Explained

A. Melt Flow Index (MFI / MFR / MVR)

  • Standard: ISO 1133 / ASTM D1238.
  • What it means: How easily the melted plastic flows. Higher MFI means easier flow, good for thin walls and long flow paths. Lower MFI usually means higher toughness.
  • Check the test conditions: MFI is always measured at a set temperature and load (for example, 220°C / 10 kg for ABS or 300°C / 1.2 kg for PC). Values at different conditions cannot be compared.
  • Read our full guide on Melt Flow Index for more detail.

B. Density

  • Standard: ISO 1183 / ASTM D792. Unit: g/cm³.
  • Why it matters: You buy plastic by the kilogram but sell parts by the piece. A lower-density grade gives more parts per kg. Glass-filled grades are much denser.

C. Tensile Strength and Tensile Modulus

  • Standard: ISO 527 / ASTM D638. Unit: MPa.
  • Tensile strength: The stress at which the material yields or breaks.
  • Tensile modulus: Stiffness. Higher modulus means the part bends less under load.
  • Elongation at break: How far the material stretches before breaking. High elongation usually means a tougher, more forgiving material.

D. Flexural Modulus

  • Standard: ISO 178 / ASTM D790. Unit: MPa.
  • What it means: Stiffness when bent. Useful for brackets, panels, and clips.

E. Notched Impact Strength

  • Standard: ISO 180 (Izod), ISO 179 (Charpy), ASTM D256.
  • What it means: Toughness when a sharp corner or notch is present. Real parts have ribs, holes, and corners, so notched impact is more useful than unnotched.
  • Look for low-temperature values (for example, at -30°C) if the part will be used outdoors or in cold storage.

F. Heat Deflection Temperature (HDT)

  • Standard: ISO 75 / ASTM D648.
  • What it means: The temperature at which a test bar bends a set amount under load.
  • Check the load: HDT is measured at 1.8 MPa (Method A) or 0.45 MPa (Method B). The 0.45 MPa value is always higher. Compare like with like.
  • HDT is a short-term test. It does not mean the part can be used continuously at that temperature.

G. Vicat Softening Temperature

  • Standard: ISO 306 / ASTM D1525.
  • What it means: The temperature at which a needle sinks 1 mm into the plastic. Useful for amorphous plastics like ABS, PC, and SAN.

H. Relative Thermal Index (RTI)

  • Standard: UL 746B.
  • What it means: The maximum temperature for long-term use (around 100,000 hours) without losing key properties. This is the better number for parts that stay hot, such as LED driver housings or motor parts.

I. Flame Rating (UL94) and Glow-Wire

  • Always check the thickness and colour listed with the rating. A grade rated V-0 at 3.0 mm may not be V-0 at 1.0 mm.
  • Read our guide on UL94 flame ratings for more detail.

J. Comparative Tracking Index (CTI)

  • Standard: IEC 60112. Unit: volts.
  • What it means: Resistance to electrical tracking across the surface. Important for switches, connectors, and terminal blocks. Higher is better.

K. Mould Shrinkage

  • Unit: %, often given in flow direction and across flow.
  • Why it matters: Tools are cut to allow for shrinkage. Switching to a grade with different shrinkage can make parts out of tolerance. Glass-filled grades shrink differently along and across the flow, which can cause warpage.

L. Water Absorption

  • Standard: ISO 62.
  • Why it matters: Very important for nylon. Nylon properties are often given as "dry as moulded" and "conditioned" (after absorbing moisture at 50% humidity). Conditioned nylon is tougher but less stiff and strong.

4. Seven Common Mistakes When Comparing Data Sheets

  1. Comparing ISO numbers with ASTM numbers.
  2. Ignoring MFI test conditions (temperature and load).
  3. Comparing HDT at 0.45 MPa with HDT at 1.8 MPa.
  4. Treating HDT as the maximum service temperature. Use RTI for long-term heat.
  5. Missing the thickness on the flame rating.
  6. Comparing dry nylon with conditioned nylon.
  7. Assuming typical values are guaranteed. Confirm critical properties with a COA or trial parts.

5. A Simple Checklist Before Approving a New Grade

  • Does the MFI suit your wall thickness and tool?
  • Is the shrinkage close to your current material, so the tool does not need changes?
  • Is the impact strength high enough at your lowest use temperature?
  • Is the HDT or RTI high enough for your heat conditions?
  • Does the flame rating cover your thinnest wall and your colour?
  • Have you run trial parts and tested them in real use?

6. Get Data Sheets and Expert Advice from Jay Plast

At Jay Plast, we provide technical data sheets and batch certificates for all the grades we supply, including ABS, PC, PC+ABS, nylon, PBT, POM, SAN, TPU, PPS, PSU, and PPSU. Our team can help you compare grades, find cost-saving alternatives, and plan trials.

We serve injection moulders, extruders, and OEMs in Mumbai, Pune, Gujarat, Delhi NCR, Chennai, Bangalore, and across India.

Contact Jay Plast today to request data sheets, compare grades side by side, and get samples for your next trial!